Sipura SPA-841 Setup
The Sipura SPA-841 IP telephone can be configured as a two (2) line or,
via a simple software upgrade, a four (4) line full featured business
phone with pixel based graphical display, speakerphone and headset port.
Stylish and functional in design, the SPA-841 can be used in residential,
SOHO, enterprise and small to medium business service offerings
including IP PBX, hosted IP telephony and IP Centrex. Out of the box, it
is configured for DHCP. This means that it gets its IP address from your
DHCP server automatically. Full documentation can be found at
Sipura's
site.
NOTE: We have seen instances where installing the SPA-841 behind a
firewall which blocks ICMP packets causes problems with registration.
Try turning off any ICMP blocking on your firewall.
STEP 1
You must first determine what IP address it received. To do this, on the
phone dial pad, press the “I” button. Using the Up/Down Scroll buttons
navigate to “Network” and press the left Soft Key labeled “Select”. The
IP address of the phone will be displayed in the “CurrentIP” field.
Write the IP address down for future reference.
STEP 2
Go to any browser equipped computer on your network and enter the
address:
http://<IP ADDRESS>/
(where <IP ADDRESS> is replaced by the address that was given to you in
STEP 1).
STEP 3
Click on the "Admin Login" button near the top right side of the screen,
then click on the "Ext 1" tab.

STEP 4
You need to modify only a few parameters from the factory default. They
are listed here:
SIP Port: 5066
Proxy: sip.cliconnect.com
Register Expires: 300
User ID: Enter the phone number you chose when you signed up for
Cliconnect service.
Password: Enter the password that you chose when you signed up for
Cliconnect service.
Preferred Codec: G729a

STEP 5
If the 2nd extension is needed, click on Ext2 and do Step 4.
STEP 6
Start calling. |